Performance analysis of a zeotropic mixture ( R290/CO2) for trans-critical power cycle | |
Pan LS(潘利生); Wei XL(魏小林); Shi WX(史维秀); Pan, LS (reprint author), Chinese Acad Sci, Inst Mech, State Key Lab High Temp Gas Dynam, Beijing 100190, Peoples R China. | |
发表期刊 | Chinese Journal of Chemical Engineering |
2015-03 | |
卷号 | 23期号:3页码:572-577 |
ISSN | 1004-9541 |
摘要 | Low critical temperature limits the application of CO2 trans-critical power cycle. The binary mixture of R290/CO2 has higher critical temperature. Using mixture fluid may solve the problem that subcritical CO2 is hardly condensed by conventional cooling water. In this article, theoretical analysis is executed to study the performance of the zeotropic mixture for trans-critical power cycle using low-grade liquid heat source with temperature of 200 degrees C. The results indicated that the problem that CO2 can't be condensed in power cycle by conventional cooling water can be solved by mixing R290 to CO2. Variation trend of outlet temperature of thermal oil in supercritical heater with heating pressure is determined by the composition of the mixture fluid. Gliding temperature causes the maximum outlet temperature of cooling water with the increase of mass fraction of R290. There are the maximum values for cycle thermal efficiency and net power output with the increase of supercritical heating pressure. (C) 2015 The Chemical Industry and Engineering Society of China, and Chemical Industry Press. All rights reserved. |
关键词 | Co2 R290 Zeotropic Mixture Low-grade Heat Energy Trans-critical Power Cycle |
学科领域 | Engineering, Chemical |
DOI | 10.1016/j.cjche.2014.04.003 |
URL | 查看原文 |
收录类别 | SCI ; EI ; CSCD |
语种 | 英语 |
WOS记录号 | WOS:000351861400016 |
关键词[WOS] | ORGANIC RANKINE-CYCLE ; WORKING FLUIDS ; SUPERCRITICAL CO2 ; TEMPERATURE ; SELECTION ; CAPTURE |
WOS研究方向 | Engineering |
WOS类目 | Engineering, Chemical |
项目资助者 | National Natural Science Foundation of China [51306198] |
课题组名称 | LHD高效洁净燃烧(CPCR) |
论文分区 | Q3 |
力学所作者排名 | True |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://dspace.imech.ac.cn/handle/311007/49915 |
专题 | 高温气体动力学国家重点实验室 |
通讯作者 | Pan, LS (reprint author), Chinese Acad Sci, Inst Mech, State Key Lab High Temp Gas Dynam, Beijing 100190, Peoples R China. |
推荐引用方式 GB/T 7714 | Pan LS,Wei XL,Shi WX,et al. Performance analysis of a zeotropic mixture ( R290/CO2) for trans-critical power cycle[J]. Chinese Journal of Chemical Engineering,2015,23,3,:572-577. |
APA | Pan LS,Wei XL,Shi WX,&Pan, LS .(2015).Performance analysis of a zeotropic mixture ( R290/CO2) for trans-critical power cycle.Chinese Journal of Chemical Engineering,23(3),572-577. |
MLA | Pan LS,et al."Performance analysis of a zeotropic mixture ( R290/CO2) for trans-critical power cycle".Chinese Journal of Chemical Engineering 23.3(2015):572-577. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
IMCAS-J2015-050.pdf(1485KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论