Depth-dependent mechanical characteristics of porcine cornea | |
Du RQ(杜睿琪)![]() ![]() ![]() ![]() | |
Source Publication | SOFT MATERIALS
![]() |
2017 | |
Volume | 15Issue:1Pages:27-33 |
ISSN | 1539-445X |
Abstract | The biomechanical characteristics of porcine corneal stroma along the depth of cornea in different anatomical orientations were experimentally investigated and quantitatively analyzed. The porcine corneal stroma tested here was cut mechanically into the three layers along the thickness of the cornea for the first time. Based on the convenient uniaxial tensile extensometry, the Young's moduli of each stromal layer in different anatomical orientations were proved to be equal to each other. By virtue of testing the mechanical behaviors of the different layers, the Young's moduli of the stromal layers were found to decrease gradually from the anterior to posterior corneal surface. Thus, the stroma was proved to be mechanically transversely isotropic. Furthermore, based on the analysis of the experimental data, the change of stromal Young's modulus along the depth of the cornea was determined to be linear and equal to - 2.79 +/- 0.967 MPa/mm from the anterior to posterior corneal surface. Finally, the linear gradient characteristic of the stroma was appropriately explained by virtue of stromal microstructures. |
Keyword | Anisotropy Corneal Stroma Linear Gradient Mechanical Properties Uniaxial Tension Experiment |
DOI | 10.1080/1539445X.2016.1242497 |
Indexed By | SCI ; EI |
Language | 英语 |
WOS ID | WOS:000394659100003 |
WOS Keyword | COLLAGEN CROSS-LINKING ; BIOMECHANICAL PROPERTIES ; INTRAOCULAR-PRESSURE ; ORGANIZATION ; STROMA ; ARCHITECTURE ; ELASTICITY ; ANTERIOR ; RABBIT |
WOS Research Area | Materials Science |
WOS Subject | Materials Science, Multidisciplinary |
Funding Organization | National Natural Science Foundations of China [11232013, 11472285] |
Classification | Q3 |
Ranking | 1 |
Citation statistics | |
Document Type | 期刊论文 |
Identifier | http://dspace.imech.ac.cn/handle/311007/72135 |
Collection | 非线性力学国家重点实验室 |
Corresponding Author | Song, F (reprint author), Chinese Acad Sci, Inst Mech, State Key Lab Nonlinear Mech LNM, Beisihuanxi Rd 15, Beijing 100190, Peoples R China.; Song, F (reprint author), Chinese Acad Sci, Inst Mech, Beijing Key Lab Engn Construct & Mechanobiol, Beisihuanxi Rd 15, Beijing 100190, Peoples R China. |
Recommended Citation GB/T 7714 | Du RQ,Tian HJ,Xu XH,et al. Depth-dependent mechanical characteristics of porcine cornea[J]. SOFT MATERIALS,2017,15,1,:27-33. |
APA | 杜睿琪.,田晗菁.,许向红.,邵颖峰.,宋凡.,...&Song, F .(2017).Depth-dependent mechanical characteristics of porcine cornea.SOFT MATERIALS,15(1),27-33. |
MLA | 杜睿琪,et al."Depth-dependent mechanical characteristics of porcine cornea".SOFT MATERIALS 15.1(2017):27-33. |
Files in This Item: | Download All | |||||
File Name/Size | DocType | Version | Access | License | ||
Jp2017308.pdf(978KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | View Download |