Knowledge Management System of Institue of Mechanics, CAS
Influence of the Realistic Artery Geometry Parameters on a Coronary Stent Fatigue Life | |
Cui XY; Ren QS(任庆帅); Li GY; Li ZH![]() | |
Source Publication | INTERNATIONAL JOURNAL OF COMPUTATIONAL METHODS
![]() |
2019-05 | |
Volume | 16Issue:3Pages:1842006 |
ISSN | 0219-8762 |
Abstract | The stents' adaptability and safety in realistic and idealized stenotic coronary model were compared to investigate the influence of artery geometry parameter on stent fatigue life. The stents' fatigue resistance ability was calculated using Goodman diagram, and the cycle to failure, the fatigue life, and the fatigue safety factor (FSF) were analyzed. Although the peak top of the von Mises stress was located at the bending area of crowns, the stress distributions were different in the two models. Considering the safety and accuracy, it is necessary to use a realistic geometric model to calculate the stent fatigue performance. |
Keyword | Biomechanics artery geometry parameters fatigue life prediction |
DOI | 10.1142/S0219876218420069 |
Indexed By | SCI ; EI |
Language | 英语 |
WOS ID | WOS:000461545200007 |
WOS Keyword | PERIPHERAL STENTS ; FRACTURE ; PREDICTION ; BEHAVIOR ; PATIENT ; DESIGN |
WOS Research Area | Engineering, Multidisciplinary ; Mathematics, Interdisciplinary Applications |
WOS Subject | Engineering ; Mathematics |
Funding Organization | Major Project of Science and Technology of Beijing Municipal Education Commission and Type B Project of Beijing Natural Science Foundation [KZ201710005007] |
Classification | Q3 |
Ranking | 2 |
Contributor | Qiao, AK |
Citation statistics | |
Document Type | 期刊论文 |
Identifier | http://dspace.imech.ac.cn/handle/311007/81446 |
Collection | 职能与支撑部门 |
Recommended Citation GB/T 7714 | Cui XY,Ren QS,Li GY,et al. Influence of the Realistic Artery Geometry Parameters on a Coronary Stent Fatigue Life[J]. INTERNATIONAL JOURNAL OF COMPUTATIONAL METHODS,2019,16,3,:1842006.Rp_Au:Qiao, AK |
APA | Cui XY,Ren QS,Li GY,Li ZH,&Qiao AK.(2019).Influence of the Realistic Artery Geometry Parameters on a Coronary Stent Fatigue Life.INTERNATIONAL JOURNAL OF COMPUTATIONAL METHODS,16(3),1842006. |
MLA | Cui XY,et al."Influence of the Realistic Artery Geometry Parameters on a Coronary Stent Fatigue Life".INTERNATIONAL JOURNAL OF COMPUTATIONAL METHODS 16.3(2019):1842006. |
Files in This Item: | Download All | |||||
File Name/Size | DocType | Version | Access | License | ||
Jp2019546.pdf(340KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | View Download |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment