Influence of Cooling Water Flow Rate on Start and Heat Transfer Performance of Pulsating Heat Pipe at Different Inclination Angles
Shi, Weixiu; Liu, Xuebing1; Su, Xiaoyang1; Chen, Hongdi1; Pan LS(潘利生)
Source PublicationSUSTAINABILITY
2023-02
Volume15Issue:3Pages:1921
AbstractPulsating heat pipe (PHP) is an efficient heat transfer technology applied in the fields of heat dissipation and energy utilization. There are many factors affecting the heat transfer of PHP, including working fluid, filling ratio, inclination angle, etc. The cooling capacity of the cooling water system at the condensing section to the working fluid is also an important factor affecting the starting and operating of PHP. The research on PHP at different cooling water flow rates is of great significance for enhancing the operating performance. An experimental investigation of starting and running performance is carried out on a closed loop PHP with ultrapure water under different inclination angles of 90 degrees, 60 degrees and 30 degrees. The starting and heat transfer performance of PHP with a filling ratio of 50% is obtained by adjusting the heat input in the range of 30 210 W at different cooling water flow rates of 6.7 g/s, 9.7 g/s and 13.9 g/s. The temperature and heat transfer resistance are used for analyzing the heat transfer performance. The results show that the starting mode, initial pulsating temperature and different heat transfer effects are brought about by different cooling water flow rates. It is observed that the cooling water flow rate has no obvious influence on the starting mode of PHP and that the starting mode of PHP is temperature progressive, starting with the increase in cooling water flow rates at a heating input of about 30 W. The influence of cooling water flow rates on the heat transfer performance of PHP is affected in a different way by inclination angles. The heat transfer performance of PHP with an inclination angle of 90 degrees is similar at 6.7 g/s, 9.7 g/s and 13.9 g/s but, under the condition of 60 degrees and 30 degrees, the heat transfer resistance drops within a certain range effectively with an increasing cooling water flow rate from 6.7 g/s to 9.7 g/s and the heat transfer performance does not change significantly with the cooling water flow rate increasing to 13.9 g/s. Thus, there is an optimal value for the cooling water flow rate during the operating of PHP. The inclination angle also has an important effect on the temperature pulsating, and the temperature of PHP affected by gravity is stable with an inclination angle of 90 degrees. However, the reduced influence of gravity on the backflow of the working fluid drops when the inclination angle decreases from 90 degrees to 30 degrees, and the wall temperature increases due to local overheating when the high heat input occurs.
Keywordpulsating heat pipe cooling water flow rate start inclination angle heat transfer performance
DOI10.3390/su15031921
Indexed BySCI
Language英语
WOS IDWOS:000929595600001
WOS Research AreaGreen & Sustainable Science & Technology ; Environmental Sciences ; Environmental Studies
WOS SubjectScience & Technology Other Topics ; Environmental Sciences & Ecology
Funding OrganizationNational Natural Science Foundation of China [52000008] ; R&D Program of Beijing Municipal Education Commission [KM202310016008]
Classification二类
Ranking1
ContributorPan, LS (corresponding author), Chinese Acad Sci, Inst Mech, State Key Lab High Temp Gas Dynam, Beijing 100190, Peoples R China.
Citation statistics
Cited Times:5[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://dspace.imech.ac.cn/handle/311007/91785
Collection高温气体动力学国家重点实验室
Affiliation1.Beijing Univ Civil Engn & Architecture, Beijing Engn Res Ctr Sustainable Energy & Bldg, Beijing 100044, Peoples R China
2.Beijing Univ Civil Engn & Architecture, Sch Environm & Energy Engn, Beijing 100044, Peoples R China
3.Chinese Acad Sci, Inst Mech, State Key Lab High Temp Gas Dynam, Beijing 100190, Peoples R China
Recommended Citation
GB/T 7714
Shi, Weixiu,Liu, Xuebing,Su, Xiaoyang,et al. Influence of Cooling Water Flow Rate on Start and Heat Transfer Performance of Pulsating Heat Pipe at Different Inclination Angles[J]. SUSTAINABILITY,2023,15,3,:1921.Rp_Au:Pan, LS (corresponding author), Chinese Acad Sci, Inst Mech, State Key Lab High Temp Gas Dynam, Beijing 100190, Peoples R China.
APA Shi, Weixiu,Liu, Xuebing,Su, Xiaoyang,Chen, Hongdi,&潘利生.(2023).Influence of Cooling Water Flow Rate on Start and Heat Transfer Performance of Pulsating Heat Pipe at Different Inclination Angles.SUSTAINABILITY,15(3),1921.
MLA Shi, Weixiu,et al."Influence of Cooling Water Flow Rate on Start and Heat Transfer Performance of Pulsating Heat Pipe at Different Inclination Angles".SUSTAINABILITY 15.3(2023):1921.
Files in This Item: Download All
File Name/Size DocType Version Access License
Jp2023A076.pdf(4492KB)期刊论文出版稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Lanfanshu
Similar articles in Lanfanshu
[Shi, Weixiu]'s Articles
[Liu, Xuebing]'s Articles
[Su, Xiaoyang]'s Articles
Baidu academic
Similar articles in Baidu academic
[Shi, Weixiu]'s Articles
[Liu, Xuebing]'s Articles
[Su, Xiaoyang]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Shi, Weixiu]'s Articles
[Liu, Xuebing]'s Articles
[Su, Xiaoyang]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Jp2023A076.pdf
Format: Adobe PDF
This file does not support browsing at this time
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.