IMECH-IR  > 非线性力学国家重点实验室
Extended-resolution of a single-camera synthetic Schlieren method for measurement of free liquid surfaces
Li HX(李慧鑫); Xu D(徐多)
Source PublicationEXPERIMENTAL THERMAL AND FLUID SCIENCE
2023-11-01
Volume149Pages:110998
ISSN0894-1777
AbstractIn a synthetic Schlieren method of measuring the height of a dynamic free liquid surface, the smallest wavelength of the measured surface topography is determined by the spatial resolution of the displacement field of markers. Currently, a displacement vector is obtained for each interrogation window, including few markers, with a cross-correlation algorithm. In this study, the measurement resolution is extended obtaining the displacement of individual markers. This simple and rational change, however, brings technical difficulties in numerically solving the governing equation over spatially randomly distributed markers. For this, the governing equation, which associates the surface height to be measured with the virtual displacements the markers, is solved by the finite-volume scheme for the unstructured meshes, where a marker locates the center of each triangular mesh face. The present method is examined with the synthetic generated data, in laboratory experiments of a transparent solid carved with a sinusoidal surface, and in experiments of water ripples. The measurement uncertainty is discussed.
KeywordSurface topography Height of free surface Synthetic Schlieren Single camera
DOI10.1016/j.expthermflusci.2023.110998
Indexed BySCI ; EI
Language英语
WOS IDWOS:001037917200001
WOS Research AreaThermodynamics ; Engineering ; Physics
WOS SubjectThermodynamics ; Engineering, Mechanical ; Physics, Fluids & Plasmas
Funding OrganizationNational Natural Science Foundation of China [11988102, 92152106]
Classification二类
Ranking1
ContributorXu, D (corresponding author), Chinese Acad Sci, Inst Mech, State Key Lab Nonlinear Mech, Beijing 100190, Peoples R China.
Citation statistics
Cited Times:1[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://dspace.imech.ac.cn/handle/311007/92577
Collection非线性力学国家重点实验室
Affiliation1.{Li, Huixin, Xu, Duo} Chinese Acad Sci, Inst Mech, State Key Lab Nonlinear Mech, Beijing 100190, Peoples R China
2.{Xu, Duo} Univ Chinese Acad Sci, Sch Engn Sci, Beijing 100049, Peoples R China
Recommended Citation
GB/T 7714
Li HX,Xu D. Extended-resolution of a single-camera synthetic Schlieren method for measurement of free liquid surfaces[J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE,2023,149:110998.Rp_Au:Xu, D (corresponding author), Chinese Acad Sci, Inst Mech, State Key Lab Nonlinear Mech, Beijing 100190, Peoples R China.
APA 李慧鑫,&徐多.(2023).Extended-resolution of a single-camera synthetic Schlieren method for measurement of free liquid surfaces.EXPERIMENTAL THERMAL AND FLUID SCIENCE,149,110998.
MLA 李慧鑫,et al."Extended-resolution of a single-camera synthetic Schlieren method for measurement of free liquid surfaces".EXPERIMENTAL THERMAL AND FLUID SCIENCE 149(2023):110998.
Files in This Item: Download All
File Name/Size DocType Version Access License
Jp2023Fa105.pdf(5608KB)期刊论文出版稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Lanfanshu
Similar articles in Lanfanshu
[李慧鑫]'s Articles
[徐多]'s Articles
Baidu academic
Similar articles in Baidu academic
[李慧鑫]'s Articles
[徐多]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[李慧鑫]'s Articles
[徐多]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Jp2023Fa105.pdf
Format: Adobe PDF
This file does not support browsing at this time
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.