Improving the radiance retrieval accuracy in limb sounding by utilizing a similarity model correcting the internal thermal radiation for an infrared radiometer | |
Ceng DD(曾丹丹)1![]() ![]() ![]() | |
通讯作者 | Li, Shuaihui([email protected]) |
发表期刊 | OPTICS LETTERS
![]() |
2024-12-15 | |
卷号 | 49期号:24页码:7142-7145 |
ISSN | 0146-9592 |
摘要 | For commercially available infrared radiometers with a small volume and a light weight and without an independent cooling system for the optical structure, thermal sensitivity is a key constraint for their application to high-precision limb observations. In this research, the response law of a medium wave (3.7-4.8 mu m) infrared radiometer with different thermal states is investigated, and emphasis is placed on the background gray variability caused by different thermal states. We construct a similarity model to describe the response difference. Utilizing the very small radiance of the upper atmosphere and the similarity model, we can correct the deviation caused by the thermal fluctuation of the sounder with high accuracy. The method of improving the retrieval accuracy is validated by simulating the limb-sounding scenarios with ground experiments. When the target radiance is 2.27 x 10-7 Wcm-2sr-1, a temperature difference of 2.5 degrees C causes a 918% deviation in the retrieved radiance, which can be reduced to 23% after correction with the similarity model proposed in this paper. This method can facilitate the application of portable radiometers in the field of high-precision detection. (c) 2024 Optica Publishing Group. All rights, including for text and data mining (TDM), Artificial Intelligence (AI) training, and similar technologies, are reserved. |
DOI | 10.1364/OL.537777 |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:001380259300005 |
关键词[WOS] | SURFACE TEMPERATURE ; CALIBRATION ; SEA |
WOS研究方向 | Optics |
WOS类目 | Optics |
论文分区 | 二类 |
力学所作者排名 | 1 |
RpAuthor | Li, Shuaihui |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://dspace.imech.ac.cn/handle/311007/97992 |
专题 | 高温气体动力学国家重点实验室 |
作者单位 | 1.Chinese Acad Sci, State Key Lab High Temp Gas Dynam, Inst Mech, Beijing 100190, Peoples R China; 2.Univ Chinese Acad Sci, Sch Engn Sci, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Ceng DD,Chen S,Chen H,et al. Improving the radiance retrieval accuracy in limb sounding by utilizing a similarity model correcting the internal thermal radiation for an infrared radiometer[J]. OPTICS LETTERS,2024,49,24,:7142-7145.Rp_Au:Li, Shuaihui |
APA | 曾丹丹,陈涉,陈豪,闫浡,&李帅辉.(2024).Improving the radiance retrieval accuracy in limb sounding by utilizing a similarity model correcting the internal thermal radiation for an infrared radiometer.OPTICS LETTERS,49(24),7142-7145. |
MLA | 曾丹丹,et al."Improving the radiance retrieval accuracy in limb sounding by utilizing a similarity model correcting the internal thermal radiation for an infrared radiometer".OPTICS LETTERS 49.24(2024):7142-7145. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
Lanfanshu学术 |
Lanfanshu学术中相似的文章 |
[曾丹丹]的文章 |
[陈涉]的文章 |
[陈豪]的文章 |
百度学术 |
百度学术中相似的文章 |
[曾丹丹]的文章 |
[陈涉]的文章 |
[陈豪]的文章 |
必应学术 |
必应学术中相似的文章 |
[曾丹丹]的文章 |
[陈涉]的文章 |
[陈豪]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论