Minimizing the thermal bridge through the columns in a refrigeration room | |
Jiang XQ1; Lin AQ2; Ma HL(马海玲)3; Li XY1; Li YY1 | |
发表期刊 | APPLIED THERMAL ENGINEERING
![]() |
2020-01-25 | |
卷号 | 165页码:8 |
ISSN | 1359-4311 |
摘要 | Thermal bridges are weakly insulated areas in the envelope of a building that can significantly increase the energy load due to heat dissipation. To improve energy efficiency, a thermal bridge model is established to simulate heat transfer through the column in a refrigeration room. The accuracy of the numerical simulation program is verified by experimental data. A heat preservation method for the column that minimizes the cooling loss is analyzed. The results show that the thermal bridging is mainly due to the steel bar in the column, because the share of the cooling loss attributed to the steel bars is 42.02-55.87%. Moreover, applying heat insulation on the column can provide more energy savings in low-temperature rooms than in high-temperature ones. The most economical thermal insulation method as a function of the height and thickness of the insulation layer is therefore proposed for the low-temperature column. By the optimum method, the amount of heat flux through the whole column section, which includes both reinforced and non-reinforced areas, decreases by 37.34%, and the total cooling loss decreases from 30.23 to 13.66 W, representing a 54.81% reduction. Therefore, a reduction in the cooling loss from thermal bridging is achieved for a low-temperature refrigeration room. |
关键词 | Refrigeration room Thermal bridge Cooling loss Column Heat preservation |
DOI | 10.1016/j.applthermaleng.2019.114565 |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:000503314300007 |
关键词[WOS] | ENERGY-CONSUMPTION ; AIR CURTAINS ; COLD STORES ; FLOW ; OPTIMIZATION ; SENSITIVITY ; PERFORMANCE ; LOSSES ; DESIGN ; MODEL |
WOS研究方向 | Thermodynamics ; Energy & Fuels ; Engineering ; Mechanics |
WOS类目 | Thermodynamics ; Energy & Fuels ; Engineering, Mechanical ; Mechanics |
资助项目 | Leading project of science and technology plan of Fujian Province[2019H0029] |
项目资助者 | Leading project of science and technology plan of Fujian Province |
论文分区 | 一类 |
力学所作者排名 | 3 |
RpAuthor | Jiang, Xiaoqiang |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://dspace.imech.ac.cn/handle/311007/81273 |
专题 | 流固耦合系统力学重点实验室 |
作者单位 | 1.Fujian Univ Technol, Sch Ecol Environm & Urban Construct, Fuzhou 350118, Fujian, Peoples R China; 2.Harbin Engn Univ, Coll Power & Energy Engn, Harbin 150001, Heilongjiang, Peoples R China; 3.Chinese Acad Sci, Inst Mech, Beijing 100190, Peoples R China |
推荐引用方式 GB/T 7714 | Jiang XQ,Lin AQ,Ma HL,et al. Minimizing the thermal bridge through the columns in a refrigeration room[J]. APPLIED THERMAL ENGINEERING,2020,165:8.Rp_Au:Jiang, Xiaoqiang |
APA | Jiang XQ,Lin AQ,Ma HL,Li XY,&Li YY.(2020).Minimizing the thermal bridge through the columns in a refrigeration room.APPLIED THERMAL ENGINEERING,165,8. |
MLA | Jiang XQ,et al."Minimizing the thermal bridge through the columns in a refrigeration room".APPLIED THERMAL ENGINEERING 165(2020):8. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Jp2020064.pdf(2182KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论