Noise reduction for temperature-sensitive paint measurement contaminated by strong background radiation in a high enthalpy hypersonic tunnel | |
Peng, Di1; Liu, Xu1; Jiao, Lingrui1; Li, Ziyan1; Wen, Xin1; Yuan CK(苑朝凯)2![]() ![]() ![]() ![]() | |
Corresponding Author | Yuan, Chaokai([email protected]) ; Liu, Yingzheng() |
Source Publication | ACTA MECHANICA SINICA
![]() |
2021-01-25 | |
Pages | 7 |
ISSN | 0567-7718 |
Abstract | The strong background radiation in high enthalpy hypersonic shock tunnels has posed severe challenges for measurement using luminescent coatings. We proposed a solution for reducing background radiation from time-resolved temperature-sensitive paint (TSP) measurement in a hypersonic flow with Ma = 6.5 and T-0 = 3525 K. The TSP was applied on an inlet ramp model, and the images were taken by a high-speed camera at 2 kHz under a modulated excitation. The strong background radiation led to a low signal-to-noise ratio and significant errors for the first half of the 130-ms test duration. Accordingly, three noise reduction methods were developed and evaluated based on temporal reconstruction, spatial reconstruction and robust principal component analysis (RPCA), respectively. The RPCA method showed the best performance that successfully recovered high-quality TSP data for a majority of test duration (t >= 40 ms). |
Keyword | Temperature-sensitive paint Time-resolved measurement Hypersonic flow Background radiation |
DOI | 10.1007/s10409-021-01050-w |
Indexed By | SCI ; EI ; CSCD |
Language | 英语 |
WOS ID | WOS:000611435000001 |
WOS Research Area | Engineering ; Mechanics |
WOS Subject | Engineering, Mechanical ; Mechanics |
Funding Project | National Natural Science Foundation of China[11725209] ; National Natural Science Foundation of China[11872038] ; Gas Turbine Research Institute of Shanghai Jiao Tong University |
Funding Organization | National Natural Science Foundation of China ; Gas Turbine Research Institute of Shanghai Jiao Tong University |
Classification | 二类 |
Ranking | 1 |
Contributor | Yuan, Chaokai ; Liu, Yingzheng |
Citation statistics | |
Document Type | 期刊论文 |
Identifier | http://dspace.imech.ac.cn/handle/311007/86020 |
Collection | 高温气体动力学国家重点实验室 |
Affiliation | 1.Shanghai Jiao Tong Univ, Sch Mech Engn, Gas Turbine Res Inst, Shanghai 200240, Peoples R China; 2.Chinese Acad Sci, Inst Mech, Beijing 100190, Peoples R China |
Recommended Citation GB/T 7714 | Peng, Di,Liu, Xu,Jiao, Lingrui,et al. Noise reduction for temperature-sensitive paint measurement contaminated by strong background radiation in a high enthalpy hypersonic tunnel[J]. ACTA MECHANICA SINICA,2021:7.Rp_Au:Yuan, Chaokai, Liu, Yingzheng |
APA | Peng, Di.,Liu, Xu.,Jiao, Lingrui.,Li, Ziyan.,Wen, Xin.,...&姜宗林.(2021).Noise reduction for temperature-sensitive paint measurement contaminated by strong background radiation in a high enthalpy hypersonic tunnel.ACTA MECHANICA SINICA,7. |
MLA | Peng, Di,et al."Noise reduction for temperature-sensitive paint measurement contaminated by strong background radiation in a high enthalpy hypersonic tunnel".ACTA MECHANICA SINICA (2021):7. |
Files in This Item: | Download All | |||||
File Name/Size | DocType | Version | Access | License | ||
Jp2021101.pdf(3477KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | View Download |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment